Are you looking for a quote on 300012-4? If so, please fill out the provided quote form below. The NSN (national stock number) is 5950013039982, and the part 300012-4 is transformer assembl by Datron Instruments Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-303-9982 Item Description: Transformer Assembl | 5950 | 013039982 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
300012-4 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 66.0 MILLIMETERS NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 7.0 MILLIMETERS NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM ALL COMPONENTS AND 440.0 HERTZ MAXIMUM ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ADAV | OVERALL DIAMETER | 72.0 MILLIMETERS NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY 1ST COMPONENT AND 3 SECONDARY 1ST COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 22.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 17.60 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 19.25 AC VOLTS NOMINAL 2ND COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
CRBZ | WINDING OPERATING CURRENT | 220.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 1ST SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL WINDING |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 2 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1500.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 3RD SECONDARY |