Are you looking for a quote on T40-0002-023? If so, please fill out the provided quote form below. The NSN (national stock number) is 5950012452649, and the part T40-0002-023 is transformer power by Harris Corporation. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.375 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT AND 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 6.0 VOLT-AMPERE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 12.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 7 QUICK DISCONNECT, FEMALE OR 7 TAB, SOLDER LUG |