Are you looking for a quote on 2139-5005? If so, please fill out the provided quote form below. The NSN (national stock number) is 5945008667147, and the part 2139-5005 is relay electromagnet by Jaidinger Mfg Co Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-866-7147 Item Description: Relay Electromagnet | 5945 | 008667147 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2139-5005 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.000 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 5.00 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |