Are you looking for a quote on FAZ-D10 3-NA? If so, please fill out the provided quote form below. The NSN (national stock number) is 5925015916139, and the part FAZ-D10 3-NA is circuit breaker by Moeller Instrument Company Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 105.0 MILLIMETERS NOMINAL |
ADAT | BODY WIDTH | 53.1 MILLIMETERS NOMINAL |
ADAU | BODY HEIGHT | 44.0 MILLIMETERS NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 17.7 MILLIMETERS NOMINAL |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT C295 |
AJEC | BOSS HEIGHT | 16.0 MILLIMETERS NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | DIN RAIL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 277.0 AC ALL LOCATIONS AND 480.0 AC ALL LOCATIONS AND 96.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS AND 10000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1000.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE AND AT POLE TWO AND AT POLE THREE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 AT 800 PCT PASCAL ALL LOCATIONS AND 90.000 18 STAGE PASCAL ALL LOCATIONS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | FAZ NA BRANCH CIRCUIT BREAKER TYPE D FOR HIGHLY INDUCTIVE LOAD |
FEAT | SPECIAL FEATURES | SUITABLE FOR APPLICATIONS WHERE HIGH LEVELS OF INRUSH CURRENT ARE EXPECTED; PREVENTS NUISANCE TRIPPING IN HIGH INDUCTIVE APPS |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |