Are you looking for a quote on 96-112? If so, please fill out the provided quote form below. The NSN (national stock number) is 5955003656722, and the part 96-112 is crystal unit quartz by Power Control Devices Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5955-00-365-6722 Item Description: Crystal Unit Quartz | 5955 | 003656722 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
96-112 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.265 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM |
ABMZ | DIAMETER | 0.335 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.410 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.017 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AEHC | III MODE OF OSCILLATION | FIFTH OVERTONE |
AEHD | CIRCUIT RESONANCE | SERIES RESONANCE |
AEHF | SHUNT CAPACITANCE IN PICOFARADS | 6.0 MAXIMUM |
AEHG | SPECIFIED FREQUENCY | 86.750 MEGAHERTZ |
AEHS | HOLDER COVER MATERIAL | METAL |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
CQBK | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.197 NOMINAL MILS AND 0.203 NOMINAL CENTIMETERS |
CQYL | DRIVE LEVEL RATING | 0.8 MILLIWATTS MINIMUM AND 1.2 MILLIWATTS MAXIMUM |
CRFX | FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT | -0.005/+0.005 |
CRMP | EQUIVALENT RESISTANCE VALUE IN OHMS | 40.0 MAXIMUM |
STYL | STYLE DESIGNATOR | HAT TYPE, 3 WIRE LEADS |