Quote Here for 2567-283 Part with NSN 5925-01-190-4474 by Reliance Comm Tec Corp

Are you looking for a quote on 2567-283? If so, please fill out the provided quote form below. The NSN (national stock number) is 5925011904474, and the part 2567-283 is circuit breaker by Reliance Comm Tec Corp. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!

Part Number :2567-283
Alternate P/N: 2567283
Item Name : Circuit Breaker
Manufacturer: Reliance Comm Tec Corp
CAGE Code : 74006

PRODUCT DETAILS

“*” Symbols for mandatory fields

CONTACT INFORMATION

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Purchasing3sixty.com is a leading supplier of CAGE code 74006 related manufacturer Reliance Comm Tec Corp obsolete and hard-to-find NATO stock number parts for aviation and marine equipment parts, deck machinery, marine hardware and hull items, pontoons and floating docks etc. Purchasing3sixty.com is owned and managed by ASAP Semiconductor, an AS9120B and ISO 9001:2015, and FAA 0056B company. We stock a large inventory of over 10 million NSN parts which are sourced from over 5,000 top NSN parts manufacturers.Use our nsn number lookup for all aviation, ship & marine parts are organized in 26 different categories with distinct supply codes.

A national stock number part is distinguished by a certain number. This number specifies the procurement, stocking, and storage of this NSN part through the federal supply system. Part number 2567-283 possess the Federal Supply Group (FSG) 5925 Circuit Breakers. This part and other NSN (national stock number) parts are an essential part of the defense and military supply chain.

Your requested quote will be answered by one of our experienced sales team. For any queries feel free to call us on our toll-free number, +1-714-705-4780, we are available 24/7. You can also email your Bill of Materials (BOM) to sales@purchasing3sixty.com to expedite the purchasing process.

NSN Information for Part Number 2567-283 with NSN 5925-01-190-4474, 5925011904474

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-190-4474

Item Description:

Circuit Breaker

59250119044740P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
2567-283523

Characteristics Data of NSN 5925-01-190-4474, 5925011904474

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH5.800 INCHES NOMINAL
ADATBODY WIDTH2.052 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.547 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.026 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.026 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.219 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.234 INCHES NOMINAL
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE40.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT FIRST LOCATION
CPRHCIRCUIT PROTECTION TYPEUNDERVOLTAGE SECOND LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 110.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
FREQFREQUENCY IN HERTZ50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
PKWTUNPACKAGED UNIT WEIGHT1.438 POUNDS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY8 THREADED STUD

 Semiconductor's Certifications and Memberships
Thank You for Visiting Us today.

Are you looking for quote within 15 minutes for your desired part? Fill an instant form and receive lowest price quote guaranteed.

Request for Quote