Are you looking for a quote on ETN 1202? If so, please fill out the provided quote form below. The NSN (national stock number) is 5925014611602, and the part ETN 1202 is circuit breaker by Spd Electrical Systems Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-461-1602 Item Description: Circuit Breaker | 5925 | 014611602 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Etn 1202 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 4.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.125 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.344 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AGAV | END ITEM IDENTIFICATION | NAEGIS MK9MOD |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED BUSHING |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS AND THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
FEAT | SPECIAL FEATURES | FOR NAVAL SHIPBOARD USE; SUITABLE FOR COMPUTERIZED DATA PROCESSING |