Are you looking for a quote on 3147? If so, please fill out the provided quote form below. The NSN (national stock number) is 5945006834040, and the part 3147 is relay thermal by Thermal Controls Div Of. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-683-4040 Item Description: Relay Thermal | 5945 | 006834040 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3147 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
THERMAL | ABHP | OVERALL LENGTH2 375 INCHES NOMINAL |
THERMAL | ADAV | OVERALL DIAMETER0 875 INCHES NOMINAL |
THERMAL | ADZC | ENVIRONMENTAL PROTECTIONSALT WATER RESISTANT AND SHOCK PROOF AND SAND PROOF AND DUSTPROOF AND WATERTIGHT AND FUNGUS PROOF |
THERMAL | APFR | CONTACT ARRANGEMENTSINGLE POLE SINGLE THROW NORMALLY OPEN |
THERMAL | AXHR | MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE |
THERMAL | CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115 0 AC |
THERMAL | CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS2 0 AC |
THERMAL | CYCU | HEATER VOLTAGE RATING IN VOLTS26 5 |
THERMAL | CYCV | HEATER POWER RATING IN WATTS4 0 |
THERMAL | CYCW | DELAY TIME IN SECONDS1 0 FIXED RELEASE MINIMUM AND 2 0 FIXED RELEASE MAXIMUM |
THERMAL | TTQY | TERMINAL TYPE AND QUANTITY7 PIN |