Are you looking for a quote on 90PK389-1? If so, please fill out the provided quote form below. The NSN (national stock number) is 5985001024200, and the part 90PK389-1 is waveguide assembly by Victor Microwave Inc. Please enter the given detail as much as possible, this information will help us to provide you the right quote to fulfill your needs. We will get back to you in less than 15 minutes!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-102-4200 Item Description: Waveguide Assembly | 5985 | 001024200 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
90pk389-1 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM FIRST FLANGE AND 0.903 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM FIRST FLANGE AND 0.403 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.407 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.422 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY AND 0.172 INCHES MAXIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.994 INCHES MINIMUM AND 1.006 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.494 INCHES MINIMUM AND 0.506 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 1.329 FEET NOMINAL |
FEAT | SPECIAL FEATURES | TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | III STYLE DESIGNATOR | STRAIGHT TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |
Are you looking for quote within 15 minutes for your desired part? Fill an instant form and receive lowest price quote guaranteed.